BBRTL - DPD NO. 3 REAGENT

  • MSDS: BBRTL
  • Manufacturer: TAYLOR TECHNOLOGIES INC
  • Product Name: DPD NO. 3 REAGENT
  • National Stock Number: 6810-00F005112
Product Identification

Product ID:DPD NO. 3 REAGENT
MSDS Date:07/01/1988
FSC:6810
NIIN:00F005112
MSDS Number: BBRTL

Responsible Party
TAYLOR TECHNOLOGIES INC
31 LOVETON CIRCLE
SPARKS, MD 21152-9201
US

Emergency Phone: 410-472-4340

Info Phone: 410-472-4340

Preparer: STEPHEN M. BACON

Cage: EO526

Contractor
TAYLOR TECHNOLOGIES, INC
SPARKS, MD 21152 US

Telephone: 401-472-4340

Cage: 89975

Ingredients

POTASSIUM IODIDE, POTIDE, HYDRIOCIC ACID, POTASSIUM SALT

CAS: 7681-11-0

RTECS: TT2975000

Hazards

Routes of Entry: Inhalation:UNKNOWN Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SKIN: IRRITATION TO OPEN CUTS. EYES:
IRRITATION. INGESTION: GASTROINTESTINAL IRRITATION.
Explanation of Carcinogenicity:NONE

First Aid

First Aid:SKIN: WASH THOROUGHLY W/SOAP & WATER. EYES: FLUSH WELL
W/WATER UNTIL STINGING CEASES. INGESTION: GIVE LARGE AMOUNTS OF
WATER. INDUCE VOMITING UNDER DIRECTION OF PHYSICIAN. OBTAIN MEDICAL
ATTENTION IN ALL CASES.

Fire Fighting

Fire Fighting Procedures:SELF-CONTAINED BREATHING APPARATUS REQUIRED.
Unusual Fire/Explosion Hazard:NOT FLAMMABLE BUT MAY DECOMPOSE UNDER
FIRE CONDITIONS EMITTING TOXIC IODINE FUMES.

Accidental Release

Spill Release Procedures:FLUSH TO SEWER OR IF DESIRED, ABSORB
W/VERMICULITE, OR OTHER INERT MATERIAL, AND CONTAINERIZE FOR LATER
DISPOSAL.

Exposure Controls

Protective Gloves:GENERAL PURPOSE GLOVES
Eye Protection:SAFETY GLASSES/GOGGLES
Other Protective Equipment:LAB COAT
Supplemental Safety and Health

Chemical Properties

Boiling Pt:B.P. Text:212F
Vapor Pres:17
Vapor Density:0.65
Spec Gravity:1.07
pH:10.5
Solubility in Water:COMPLETE
Appearance and Odor:COLORLESS, ODORLESS, WATERLIKE SOLUTION
Percent Volatiles by Volume:80

Stability

Stability Indicator/Materials to Avoid:YES
OXIDIZERS & ACIDS
Hazardous Decomposition Products:REACTION W/OXIDIZERS & ACIDS WILL
LIBERATE IRRITATING FREE IODINE.

Disposal

Waste Disposal Methods:FLUSH TO SEWER OR IF ABSORBED W/INERT MATERIAL,
DISPOSE OF BY INCINERATION OR OTHER METHOD APPROVED BY LOCAL, STATE
OR FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.